John asked ... How can I mend my binatone veva 1210 handset?    |    Kurt asked ... How can i mend my Aiwa HV-FX7700K?    |    Laetitia asked ... Toyota overlocker model 3400 D?    |    Jo-Anne O'Mullane asked ... Clear E1 error code on smeg dishwasher with no water or leak?    |    MRG asked ... Trayford close coupled toilet?    |    Click here to ask your question

Jaguar boiler F1 code?

Hi the have bin installing a new pcb board and a gas valve still the F1 code keeps on the display and the boiler wont start is there anybody that hase experience this problem .
Freddy, August 2017
Now already 3 poelpe csme to look at it seems none of them now how to fix it

Freddy, August 2017
Now already 3 poelpe csme to look at it seems none of them now how to fix it

Freddy, August 2017
You, Sir, are welcome.

Good luck

Acp, August 2017
Thanks for the feedback ACP.
As a engineer came and start changing every time a part guessing witch one it was i think i planed to have a qoute for a new one becouse already old one i think.
But recently i take of obe of the led of the pressure switch and the code didn't appear any more when putting it back the code f1 came back;s i presume that one is the problem.

Freddy, August 2017
All the relevant answers you are likely to find were in those links. To summarise:

F1= no flame detected

Likely causes:

* No gas or faulty gas valve
* Check flame electrode and cable for defects
* Check ign unit on gas valve
* Check fan operation
* If boiler has overheated reset the overheat sensors located on the left hand side pipework - little red switches on a sensor attached to the pipe.
* CVI unit could be faulty
* Possibly air pressure switch

I believe jaguar boilers were made by Glowworm. I also believe that Glowworm offer fixed price fixit. I have used them myself on two occasions. the advantage of getting the maker to do the job is the engineer will have specific product knowledge and will have a van full of product speciific spares - they are also reasonable price.

Oh, they are also Gas Safe certified so can work legally on gas installations, whereas those who are not certified cannot legally do so.

Acp, August 2017
I dont see any relevant answer. A ingeneer did the job so i expect it to be done good.the reset button dont help.heat plate exanhaser is free not stuck .the water insude is all clezn. The pump is working. The ventilation fan is working???

Freddy, August 2017
https://www.diynot.com/diy/threads/jaguar-28kw-not-igniting-from-cold-f1-fault-code.57782/ (Note especially item #5 - Have the repairs you did been done PROPERLY? Will anything else be done properly?)

Other stuff:

https://fixed4free.com/answers.php?id=258937

http://forums.moneysavingexpert.com/showthread.php?t=1298265

Acp, August 2017
link Click here to see other fixes for Jaguar.