Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Click here to ask your question

Alarm not going off?

I have a 700L C&K Securitech house alarm system.
When I put in the code No. 5 (REDLIGHT IS ON, not flashing)
After setting the alarm with the code, the alarm does not go off, just a continuous ringing tone.
At this stage it should go off!
To get rid of the ringing tone I have to reset it with the code again.

So, basically the alarm is not functioning.
The Buzzer/Ringer is working, as I tested it.

Thanks,
Steve
Steve, November 2022
Hi Steve, whatever type of sensor on zone 5 is indicating that it is “open”. At the end of the exit time, as it is still open the exit tone continues to alert you to this fact. You need to find out what zone 5 is, and fix that. Just for your info the system although continuing to make the exit noise will in fact have set, automatically omitting zone 5.

If other pirs on the system are ok, ie have power at them, i suggest it may be a door contact which has failed. Best to find out what zone 5 actually is before going any further.

Alan, November 2022
link Click here to see other fixes for 700L.