3 hours ago Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    Click here to ask your question

jaguar 23kw combi boiler fault?

hello.called out to a jaguar boiler(which ive only ever installed ...never had to repair one)the fan starts and then cuts out when air pressure switch makes contact ie fan cycles on and off constantly.fault on both heating and hw...air pressure switch appears ok ...suspect pcb maybe?...any help welcome
stu, August 2007
ignition module on the side of the gasvalve faulty

gasmanmark, August 2007
After the fan starts and the air pressure switch makes, do you get a spark at the burner or does it cut out before then?

Neil (Baxi engineer), August 2007