Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

Overheat light always on on Creda Florida Plus shower?

The overheat light will not go off and the shower is just giving out cold water. how can i fix it? The power light is on, Full Heat light off, Half Heat light off.
The overheat light does go out if set to Cold (it has cold, half heat, full heat settings). I've noted that there seems to be no difference in the water flow.
Thanks in advance.
Sach, May 2008
you need to replace the thermal cut out, it sits on top of the water tank held down by two nuts. this problem is usually down to the water flow not being sufficient.

matthew jackson, May 2012