Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    John asked ... How can I mend my binatone veva 1210 handset?    |    Kurt asked ... How can i mend my Aiwa HV-FX7700K?    |    Laetitia asked ... Toyota overlocker model 3400 D?    |    Click here to ask your question

heatstore aqua plus overheat light on constant?

hi my heatstore aqua plus shower has the overheat light on constantly,wont go off even after running for 10mins. Cold shower so not any use. Any ideas to mend? Thanks
gaz, July 2009
My overheat light is on permently and runs cold all the time not able to see a reset anyware

Raymond, July 2022
This worked. Cheers

1wri8, February 2022
I have an Aqua pLUS electric shower 3 years old & about 1 year ago the element burned out and the element had to be replaced. 3 months ago the element overheated and tripped - so untripped it. But now this has happened again. The water pressure is fine downstairs & the previous shower was installed 5years + and no problems.. Should I put in a new shower or how best resolve Thks

hARRY, February 2015
Perfect fix thanks !!

Paul, February 2014
Exactly the same symptoms, shower works ok on all heat settings but when the off button is pushed the water stops flowing but the overheat light comes on and you can hear the water boiling before the thermal cutout turns off the power but leaves the over heat light on. I now make sure the main ceiling pull cord switch is turned off. Any advise welcomed please.

mdn1812, August 2013
siyron, did you ever figure it out? I'm now having the same problem. Resetting the heat sensor gets the shower working again (water heats up), but every time you turn it off, it makes the boiling noise and the overheat light returns.

Rafiki, August 2013
Thanks everyone who answered this problem. It worked. However why does it sound as if it is boiling and the overheat light come on every-time the shower is switched off? I even tried running it on cold for a while (it actually doesn't run completely cold). Still the same. Anyone know?

siyron, June 2013
hi i had that problem and i fix it but now after press off the shower still working.I mean water not going but i hear its working and after steam going from the head
What now??

cez, May 2013
Genius, thank you so much 22lee and co!

It was hard to tell if the plate in the thermal cutoff (TCO) had been reset. I just pushed it back in. But it did make a "click" sound the first time I pushed it. I then replaced all the parts and, voila, a working shower.

benbland, March 2013
As below, this solved my problem - wish I'd have found it before my guests left after having cold showers! I wasn't sure what was meant by using a screwdriver to push back the metal plate but underneath the thermal cut-off there's a metal switch that needs clicked back into place, easy enough to do but hard to explain in words. Very easy fix that will be apparent when you get the nuts off.

Cheers lee22!

Kevin, December 2012
22lee is completely right with his method.
Pushing gently back the metal plate in the heat sensor did the job. Saved us 65 gbp.

Berry, June 2012
Russell's answer is right on.Just remember you dont have to take the nuts right off silly me.

Thanks Russell

Stephen, January 2012
Would like to say huge thanks, just completed your solution and it has worked perfectly, I thought I was going to have to payout for a new one!!

Russell, October 2011
you have to kind of reset itfrom the heat sensor,disconect the power from the main,open the front cover ,on the top left abovt the heating element undo the two nuts to release the heat sensor ,use a screwdriver to push the plate (on the heat sensor)back in.

22lee, September 2009