1 hour ago Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

mira sport 10.8kw fault?

There is little pressure. On full power it is cold for a good half a minute or so and then works the same as on medium but low pressure. Seems as though max power is not working.
Has worked fine for 3 years or so.
Any ideas please
Rick, December 2009
Likely to be a fault with heating element.
Power off the appliance at the main switch.
The elements can then be checked with a mulitmeter.
Typical resistance reading should be about 14 ohms for each element section.
If in doubt call an electrician to assist.

garryk, December 2009