3 hours ago Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

How can I fix my Triton Shower T90si 9.5kw Power Shower?

When the shower is running after a few minutes it trips the electric! It seem to happen as you turn the heat up restricting the water flow. It seem fine on very low heat setting and runs o.k as tepid!
Edmund G Galloway, April 2006
I checked the the breaker and it is 40amp. It is also a seperate switch to the shower. The shower runs o.k on low heat settings 6,7,8,9 but when turned to high heat 'two red wave lines' in trips this 40amp then the main house breaker board. All the electric goes off! We have had this shower for about 5yrs.

Edmund G Galloway, May 2006
Check that the circuit breaker (should be a residual current detector really) is 40 amp or greater, the heating elements come on in stages as you require them with this shower, so it could be as the electrical current demand increases that it exceeds the rating of the breaker.

Mikeydsparks, May 2006