Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

Hoover TV630 - connections to timer?

Have replaced the control board successfully, following a fault with the ON switch. However, accidentally the negative spade connector (holding 2 blue wires) to the timer had come loose. Which terminal on the timer should this spade terminal be attached? I have connected it to the one besides the other negatives at the bottom end of the timer, and the drier runs. However the timer is not working correctly as it does not switch off when the timer cycle has completed. Anyone know the correct connector?
Jolly traveller, January 2012
Thanks. Looking very carefully, spotted a 'clean' spade half way down, one of 2 linked. M/c works fine now.

Jolly traveller, February 2012
cannot lay my hands on a wiring diagram for the tv630 but if you look at the timer again the wiring spade will have left two strokes on the terminal it came off which should be common to one of the leads off the timer motor

keymatic, January 2012
link Click here to see other fixes for Hoover TV630.