3 hours ago Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

Bosch tumble dryer WTL 6300 not heating up?

My Tumble dryer is 5 yrs old condensor type and is not heating up,it has power and the drum appears to turn what is the likely fault and can i fix it myself? The extended warranty ran out on 2/12/06 !! I have cleaned the condensor unit.
Joan Ritchie, December 2006
Turn off the power and unplug it.

remove the cover on the back - torx fittings about a dozen.

At the top you will see a couple of black electrical connectors - one has a small red button.

Press the red button - if it clicks then you have fixed it. This is the overheat protection.

Make sure that the filter and the internal filter are clear - this is the most likely cause ov overheating.

mark, January 2009
link Click here to see other fixes for Bosch.