Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

Heater blows Hot & Cold?

I have a LDV convoy mini bus 2002 Duro engine. Heater works when moving but when stationary blows cold
Nal, March 2017
Check water pump is circulating water ok and also there were lots of problems with heater control valves on these,take off the passengers footwell side panel for a look and check the operation of the cables and the valve itself,might be worth removing the heater rad while you are there also and check the fins for blockage and give it a flush out too,good luck.

cdc, March 2017