Dave asked ... Repair kettle lid?    |    Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Click here to ask your question

HOW DO I REPLACE THE PRD ON MY TRITON OPAL SHOWER?

I have a seven year old Triton Opal shower. It has never been brilliant and has seemed to run hot and cold during use. We haven't used it for some years and I've just had a go at 'fixing it'. As soon as I turned it on, the overflow pipe at the back shot out water. On reading the User Guide (yes, I still have it!), it appears the Pressure Relief Device has operated. It says that it must be replaced (not just reset). There is a picture of the part in the User Guide but, having openned the front of the unit, I can't see it! I presume it is inside or behind something else? Can anyone tell me how to find it and how easy it is to replace?
Martin, September 2007
it's at the bottom of the heater tank. should have a plastic pipe attached.

10 mins to fix. then you must recommission the shower tells you how in the book

as for the hot / cold problem sounds like a faulty flow/stabilizer valve.

hi-spec plumbing, September 2007