Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

My ferroli modena 102 pilot light keeps cutting out?

how can I stop my ferroli modena 102 pilot light from going out and then coming back on every 10-15 seconds. How do I service this boiler ? What parts would I need? does running sentinel through my radiators help or is it a waste of time? That and many more questions.
Regards Colin Gill
Colin Gill, December 2007
fit a new gas valve, part No 39808000, it just worked for me

Ken, December 2007
fit a new gas valve, part No 39808000, it just worked for me

Ken, December 2007
right for the three people who have the same problem there is only one of four possibilities firstly and the most common is the fan is not removing the burnt gases quick enough causing the boiler to reach temperature to quickly to check this remove the front combustion cover if it stays on thats your problem secondly change the thermistors thirdly check the air pressure switch(very unusual) and last but not least sometimes the plug which goes on the thermistor is to slack not a good contact

ricky, December 2007
best bet is call out british gas (or ya local boiler man/woman)

PedRo, December 2007
link Click here to see other fixes for Ferroli.