Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

13A Fuse Blowing?

I have a new Al-KO 3Kw Log Splitter which is supplied with a standard 13amp plug. When I first switch on, the 13amp fuse in the plug blows. Once this is replaced I can switch on and off with no problem during that day. When I go to use it again the next day, the initial "switch on" will blow the fuse again. Any suggestions please ?
Robert Peggie, January 2008
Hi
It is the surge current from the 3kW motor that is blowing the fuse,if you have an electric cooker try plugging the 13 amp plug into the 13amp socket on the cooker supply,if this is not possible you'll need to get its own isolated supply.
atb

holly, January 2008