Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

Ferroli Modena Combi: Hot water turns off after a few seconds?

Ferroli Modena 102 Combi Boiler: Fires up for hot water but goes out after a few seconds.
Any suggestions as to the problem or a suggested repair?

Ta
Nick W, June 2005
Had the same problem - you need to replace the hot water flow temperate sensor (two minute job). Part available from plumb centre - part number 800320 (E23-839).

How to fit:
Remove outer casing and retaining bars from control panel to gain access. The sensor is located on the output of the hot water pipe (left hand side - facing the boiler).
Isolate power to bolier.
Turn water off - open tap to reduce pressure.
Remove connector to sensor.
Replace sensor - reconnect and refit casing
Turn water and power on and test.

Adrian, July 2005