20 mins ago Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    Click here to ask your question

I have run out of oil recently?

I have run out of oil recently and have refilled the tank. I am following the instructions to restart the lockout but it keeps locking out. I have a firebrand oil combi boiler with a riello burner. Can you assist.
Carl Barnett, February 2008
You need to bleed the airlock from the pump, read a few of the previous posts on it.

You may need to fdo this more than once, especially if you ran the burner until it was out of oil ans there may be quiet a few air pockets in the oil line, so stick with it.

It will fire, sometimes for even a few minutes then happen again.

If you still are having no luck, post a reply.

Tony, February 2008