David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    John asked ... How can I mend my binatone veva 1210 handset?    |    Click here to ask your question

Is my Potterton Mini Minder Control faulty??

I have a Myson Apollo boiler and a Potterton Mini Minder E control panel. The pilot light seems to be lit in the boiler but when the heating and hotwater are suppose to come on automatically nothing happens, is this a faulty control unit? It's as if there is no spark to ignite and make the boiler fire up!!

I have no idea about boilers etc, any help would be appreciated.
Thanks,
Emma
Emma Graham, April 2008
the pilot light is whats there to light the boiler up.
the problem is the gas valve is not opening up for the main burner.
basically when your programmer calls for heat via stats, live should be sent to boiler thermostat and providing its not satisfied, live will be sent on to gas valve to open up and allow gas to burner. it would involve tracing how far power is getting along the line.

make sure programmer is switching power
stats are callling
boiler stat is calling
power is getting to gas valve

z, April 2008