Freya asked ... Frister & Rossman Cub7 Sewing Machine?    |    katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Kathy asked ... Samsung ER-4915?    |    Click here to ask your question

Filling up my boiler-Glow Worm30HXI?

I have a fault F5 showing on my Glow Worm 30HXI boiler. How do I fix this. I have no instruction booklet. Thanks H
H Garbutt, April 2008
F5 is an overheat fault, due to maximum temperature being exceeded

Check both the overheat stat and ch thermisters
Possible air in the system, make sure system pressure is 1-1.5 bar and all air has been bled from the system
Check pump is working correctly and does over run when boiler reaches temp.