Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

how can i fix this problem? ferroli Optimax 25c boiler?

My heating and hot water do not come on. i have a ferroli optimax 25 c boiler. the display fault is as f 01. What could the fault be? The boiler fires up 3 times then goes back to f 01.
Steve, June 2008
Ignition unit on gas valve prone to cause this fault. Check electrodes & gas valve/solenoid first. Ignition unit needs to be set for combi boilers via main pcb.

Gazza, September 2010
this is a burner ignition fault alarm, would guess from what you have described it is a flame rectification probe/lead problem and they will either need cleaning/repositioning or replacing

T, June 2008