katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Kathy asked ... Samsung ER-4915?    |    Mark asked ... Oven door removal?    |    Click here to ask your question

how can i fix my glowworm combi 100e boiler - the pressure has dropped to 0?

Pressure valve has droped to 0
rachel murray, July 2008
Hi Rachel, if you look under your boiler you will see a large pipe on the left. Follow this pipe and you should see a junction where a smaller pipe is connected, this pipe will have a silver coloured valve. There should be a flexible pipe (usually covered with a metal mesh) this should be connected to a valve with a lever on it turn this lever slowly and you should hear the sound of water going through the pipe. Watch the pressure guage and let the pressure go upto 1.2 bars then close the lever. Job done...
But more importantly do you know why your system has lost pressure?

Mick, July 2008