ariston micro genus 27mffi flame comes on for 5secs then goes to lock out w?

flame goes out after 5 secs then goes to lock out
gtg, August 2008
pc board sometimes causes this fault

sts heating, August 2008
flame proving device us

derekfromblackburn, August 2008
is it condensing? if so check condensate trap should have water in it up to given mark. also check pump as could be ceased, check for air, for air lock, make sure air vent is open, check for blockage.

IHS, August 2008