room stats?

I have a vaillant turbomax vuw gb282,can I fit a room stat and if so how,As I cannot find the data sheet.thankyou.
david lucas, August 2008
turn off power at fused spur or socket, then you drop down the main control panel at the front, (two plastic screws on top left and right corners), remove control board cover, on the front right side of the board you'll see a terminal block, live neutal earth etc. terminals 3 and 4 are the stat live and switched live respectively terminal 5 is neutral for the stat anticipator.

tojo, August 2008