3 hours ago Pekaye asked ... Clutch Cable change?    |    4 hours ago Richard asked ... Mountfield SP414 mower, revs too high?    |    Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Click here to ask your question

Bathroom Light?

I have removed all the fittings to my bathroom light and there are three groups of wires hanging from the ceiling. I need to put the fittings back to how they were originally (long story). the wires are:

1. Bare copper, red, black
2. bare copper, red black
3. bare copper, red, red

also....there is the rose part where the buld twists into which has two brown wires.

The places to screw in the wires are little screw holes which are groups as 1,2,3, 1,2,3 1,2

can you tell me how to re-wire these back in. It appears that the bathroom light is a loop for the other lights upstairs.

Please help
kheselden, August 2008
from what you say the loop is cable 1 and 2, so join these
together bare copper to bare copper ( earth ),
red to red ( live ),
black to black ( neutral ).
this should enable the rest of the lights to work
but NOT the bathroom light.
To connect the bathroom light you need to connect cable 3.
bare copper to the other bare copper (earth), also if
your light fitting has a earth wire (green/yellow)
connect this as well.
ONE of the reds to the other connected reds (live),
the brown wire of the light connects to the other red (switched live).
connect the blue from the light to the 2 connected black (neutral).
If in doubt call an electrician.