Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

my boiler is not cutting out and radiators very hot?

as above - vokera boiler
angela, October 2008
Or perhaps the DHW microswitch is stuck in the 'demand' position. To check see if the burners are modulated by turning the hot water temperature setting dial up and down, also if microswitch is faulty CH will stay on when in 'summer' mode. Hard to say more without the model.

c, October 2008
your boiler main thermostat is knackered causing the boiler overheat thermostat to operate.there are also other reasons which could cause this ie bypass radiator shut off/boiler bypass closed/ corrosion in main heat exchanger and radiators

stevie w, October 2008