Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

Worcester 24i rsf no hot water?

I followed the fault diagnosis and replaced the flow switch. However the boiler reset kept tripping out (overheat thermostat). I replaced this and the heating is working perfectly but no hot water at all. When there is demand for hot water the boiler does nothing - like it hasn't detected it at all - the fan doesn't start, nothing! What's next? Could the new flow switch be faulty?
Rob, October 2008
Easy enough to check - use a multimeter and check for continuity through the two pink wires when a tap is running.

If switch is making, and boiler not responding, then board fault.

BunSlinger, October 2008
link Click here to see other fixes for Worcester 24i.