Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

combi boiler locks out after using hot water?

i have a potterton puma 80e combi boiler.after running hot water and turning the tap off the boiler makes a loud noise as if over heating and the system locks out,red light comes on.press reset and it is fine.does not seem to play up on the central heating side.
steve, January 2009
d.h.w. flow switch may be sticking,causing the boiler to stay on after tap is turned off resulting in the boiler overheating and shutting down.....this happened to me,i removed,cleaned and setup the d.h.w. flow switch and has been ok since...hope this helps.

Dale, November 2009
domestic hot water heat exchanger might be blocked with limescale.this in turn causes an overheat in the system.

a1, January 2009