Dave asked ... Repair kettle lid?    |    Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Click here to ask your question

Potterton Envoy 80 working erratically?

My boiler, a Potterton Envoy 80NG, would heat up but there was no certainty that it would remain hot. I fiddled with the dry fire sensor and that seemed to have cured the problem. Problem returned after 2/3 weeks so I had the sensor replaced. That was 3 weeks ago but the problem has returned. Fiddling with the sensor as before has brought the heat back up. I suspect the electronics. Can I get information on the printed circuit board used.
John Connolly, December 2005
My Potterton Envoy 80 works errartically also. Mine fails to fire up quite frequently and we are always having British Gas out to fix it. My wife says they say its somerthing to do eith the flue. I looked at the diagnostic message today and it kept showing 'F' indicating there was low gas pressure. This seems to fit with the ongoing failures as the pilot light fires up but it doenst hold the flame (andf then keeps firing for the cycle of four and then times out 't'.
Any ideas anyone

Jon B West London, January 2010
call out someone who knows how to strip down the boiler completly,heat exchanger may be blocked on flue side,replace flue hood seal,top gator seal,sump seal,ignitor and flame sensor seal,make sure syphon unit is clear,worth paying someone to do this who is familiar with envoys
paul conneelly@acwilgar.co.uk

paul conneely, January 2006
link Click here to see other fixes for Potterton.