Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    Click here to ask your question

halstead ace high boiler shutting down?

halstead ace high boiler fires up for aprox 5 seconds then shuts off. does not lock out but green power neon flashes. has no power to pump from terminal at pcb. have to reset flashing power neon by turning off at main switch to boiler
richard, January 2009
my halstead CH after 10 second turn off.can some body solve my problem?

sam, September 2012
it is the pump proving switch either micro switch breaking down or diaphragm

gasman 78, November 2010
Hi I think that has something to do with the pump. I had the same problem and I found pump was faulty.

Andy, January 2010
Did you find an answer as myn is also doing this!

Mark Smith, October 2009
link Click here to see other fixes for Halstead Ace High.