Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

Worcester 24i intermitent?

My 24i wont come on in the mornings, the pilot light seams to light very weak then goes down/off. After flicking the electric on and off a few times its ok and stays on fine, that is until its set to auto and may or maynot refire.

I had a plumber take a look and hes not 100% sure, I guess hes not familiar with this boiler.

I had it serviced and the fan greased up (aparently it was a little dry) and every morning the heating is off. And we all know how cold it is at the min....

Any advice is greatly appreciated.
Matt, February 2009
greasing a 24i fan!-well whatever next?
well budd! Had a lot of experience with this boiler and this sounds like main printed circuit board has duff intermittant relay etc ( not cheap and later new boards a bit hiss and miss on quality control side,but you find worcester admtting it!I know it might be a pain,but personally I would suck it and see and await the permanant breakdown that confirms it.

chris the gas, February 2009