John asked ... Scantronix 9450 box stuck shut?    |    Pekaye asked ... Clutch Cable change?    |    Richard asked ... Mountfield SP414 mower, revs too high?    |    Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Click here to ask your question

water coming from blow off pipe ?

halsted finest gold (what a joke) water coming from blowoff pipe , pressure dropping then boiler cutting out , keep refilling bolier but same happens . help plz .
jonathan neal, February 2009
the safety valve is passing slightly,could be a bit of grit on the valve seat or maybe the spring is getting weak.Try opening the boiler casing and look for the valve,it might have a manual override(sometimes a lever,sometimes a cap that you can turn,once you know it has a manual discharge try opening valve by hand to see if you clear any grit,if not then its easier just to replace valve,they aren't too expensive and quite easy to replace,remember to drain system first.

steffdaplum, March 2009