Sharma asked ... Replacing pin for belt guard Ranch King Pro 14AT818H205?    |    Freya asked ... Frister & Rossman Cub7 Sewing Machine?    |    katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Click here to ask your question

Glow worm 30sxi. Condensing Boiler?

Glow worm 30sxi High efficiency condensing Boiler. No pressure! Rads bled, no air locks. Why has it never worked properly?
julie, March 2009
will it run a heating and hot water

nick, March 2013
If there's no pressure, then you need to re-pressurise via the filling loop,usually the chrome valve and flexible tube near to the boiler. If pressure is constantly going down,then you need to either look for a leak or,if the pressure rises very quickly on fire up you need to check the expansion vessel.The 30sxi is normally avery reliable boiler.

Phil the plumber U.K., March 2009