Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

no hot water?

we have a sime combi boiler and can not get hot water to the taps but the c/h is all ok can you please help
keith, April 2009
it is more than likely to be ur diverter valve which diverts ur hot water to ur central heating this may need to be replaced

jm, April 2009
it's the diaphragm inside the diverter valve that has failed. you don't need a full diverter valve (these are about £90) you can get the diaphragm on it's own for about a tenner

andy gas man, April 2009
Domestic hot water diaphragm has probably failed

andy gas man, April 2009
Your boiler has a diverter valve inside, that directs the hot water either to the taps or the radiators, and I guess it has packed in.

John, April 2009