David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    John asked ... How can I mend my binatone veva 1210 handset?    |    Click here to ask your question

Heating my hot water system?

We have a 210 litre megaflo tank and our boiler is an oil fired Boulter Camray 90/110 but it will not heat the hot water unless I set the Danfoss motorised valve to the manual position, I bought a new motor for it yesterday and replaced it but the problem is still there, any ideas please?
John, May 2009
Sounds like you are not getting a 230v supply to the Motorised Valve, are you sure the Overheat stat has not tripped? it is inside the control cover on the Megaflow

You should have any Un-vented Hot Water Storage System Serviced Annualy by a G3 Qualified Technician to comply with Building Regulations it is Illegal for NON G3 Persons to interfere with these systems

www.elanar.co.uk, May 2009
link Click here to see other fixes for Danfoss Camray.