Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

Heating my hot water system?

We have a 210 litre megaflo tank and our boiler is an oil fired Boulter Camray 90/110 but it will not heat the hot water unless I set the Danfoss motorised valve to the manual position, I bought a new motor for it yesterday and replaced it but the problem is still there, any ideas please?
John, May 2009
Sounds like you are not getting a 230v supply to the Motorised Valve, are you sure the Overheat stat has not tripped? it is inside the control cover on the Megaflow

You should have any Un-vented Hot Water Storage System Serviced Annualy by a G3 Qualified Technician to comply with Building Regulations it is Illegal for NON G3 Persons to interfere with these systems