1 hour ago Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

potterton dead?

Hi, my Prima F is not firing up despite c.h and h.w. being on, I've tried to rest it but there is no "Click"
Thanks
Dave, July 2009
has your boiler got power to it does it make any noise fan running? if your fan is not running. with a multi meter check for a 230v. is the pump running? this will tell you if your motorised valve is working both stats calling for heat? also check aps if the fan is running. u can blow down the tubes from the fan and your boiler will start to ignite. if nothing at all and if you feel confiden isolate the power and remove the pcb and check for black marks had a few pcb's go on this boiler

Nathan, July 2009
why have you started another post for same problem ?
have the checked if the pumps running ?

hi-spec plumbing & heating (essex), July 2009
link Click here to see other fixes for Potterton.