Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    HT asked ... Radio code Philips 22RC200/35?    |    Roberta asked ... DW5080?    |    Dave asked ... Toilet Push Button not flushing properly?    |    Click here to ask your question

How can i fix my Radiators?

My upstairs radiator are working fine but ground floor are cold pump is working fine tried bleeding but no air has been found Help if you can
B.Brown, October 2009
It may be that the upstairs radiators are using up all the available heat before the pumped radiator water reaches the downstairs rads...

Turn the upstairs rads fully off - if downstairs rads now start to warm up you know the likely cause.

You can balance the radiators by adjusting the lock shield valves (closing off the outlet valves a bit) particularly on the upstairs rads - see...

http://www.miketheboilerman.com/balancing.htm

You can increase the temperature of the water from the boiler a bit but not too much else the tap water may become too hot - you can sometimes speed up the circulating pump to get the water around the system a little quicker.

This answer is close to worthless because I have no specific expertise in heating systems - but it might work...

Good luck...

Peccavi, October 2009