Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

How can I top up water pressure Vokera Mynute 14se?

I bled my radiators and the water pressure fell to 0. I dont where to top up the pressure as I dont have the manual. Can any one help please, the radiator will not ignite anymore and its freezing here!!! Please help!
Shivering Olaf, March 2006
Thanks Scott, couldnt have been a more straight forward job but I would have had no idea without your reply.

Steve, April 2010
Scott, thank you so much for your simple and straight forward answer. It helped us out!

Elin & Elsa (8 months), February 2009
On the pipework below the boiler should be a filling loop which is a chrome braided hose with valves at either end. Open the valve(s) slowly to top up boiler. Shut again when up to 1-1.5 bar on pressure gauge.

Scott, April 2006
link Click here to see other fixes for Vokera Mynute 14se.