Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

potteron profile 100e, hot water, no central heating ?

can anyone shed some light on the matter? we have no problem with the DHW system, but we have no CH at all. What was happening is, the boiler would light up then it would go out out after about 10-15 seconds then not come on again for about 5-10 mins(times are aprox only) so from this you can see no CH.
slinky, January 2010
profile is not a combi, so it will be either a faulty zone valve, or a faulty pump if you have a gravity hot water system.

Ian, January 2010
The diverter valve is stuck in DHW mode. May be caused by a dripping DHW tap, or may need a new diverter valve.

Henry, January 2010
link Click here to see other fixes for Potterton Profile 100E.