1 hour ago Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

Grundfos Selectric UPS 15-50 pump?

We have recently moved house and have inherited this pump. It never seems to stop running, day or night, even with the boiler off. Surely this can't be right?
Malcolm, February 2010
sounds to me that the actuator is stuck open on the 2 or 3 port valve, only thing that will over ride programmer etc (plastic box with a wire coming out of it sitting on a brass body on the heating & hot water pipes normally in the airing cupboard)

plumb bum, May 2011
Check and see how it's been wired up.

Typically it should be under the control of the boiler - if so, then the boiler over-ride electrics are poss faulty.

What is the boiler??

Mike the boiler man, March 2010