John asked ... Scantronics 9450 box stuck shut?    |    Pekaye asked ... Clutch Cable change?    |    Richard asked ... Mountfield SP414 mower, revs too high?    |    Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Click here to ask your question

suprima 50 red light flashing?

I have changed the board on my suprima at Christmas worked perfectly up to now. The Red light is flashing when I reset it tries to come on but does not ignite gas the igniter seems not to sound strong. After trying to light it gives up and tries again.
Simon, February 2010
this could be the fan running and sounding ok but actually running too slow, to open the air pressure switch and fire the boiler, slightly open the door during the ignition sequence and if the boiler fires its probably the fan, if not it may be your air pressure switch, i think unlikely such a new circuit board to have failed but of course it is possible

john, March 2010
link Click here to see other fixes for Baxi Suprima 50.