Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

alpha boiler cb24?

my alpha cb24 boiler looses pressure every 20 minutes i fill up boiler in 20 mins its empty happening every day no heating and hot water any help please
terry, March 2010
Sounds like you need a new expansion vessel. To confirm this, have a look outside where the boiler is. There should be a 15mm copper pipe coming through the wall about 3 feet below the flue pipe (normal istallation) if this pipe has evidence of water loss (ie dripping) then you probably need a new vessel inside the boiler or the safety valve could just be stuck.(CAUTION THIS WATER MAY BE EXTREMELY HOT) If no evidence of water is present then you have a leak in the system somewhere - if this is a upstairs leak then you will see water patch on downstairs cieling soon enough.
I would say most likley vessel as 20mins is very quick for pressure drop.

Stewiesnake, March 2010