Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

alpha 240P boiler?

I cannot reduce the pressure on my boiler even after bleeding the radiators, is there something simple I can try before calling in a professional? Or is it completely broken ....
Caroline Thomas, April 2010
filling loop (the bit you use to top the pressure up) may be passing or plate heat exchanger may be burst. try disconnecting the filling loop hose to prove if it's passing, be ready to turn the water mains off in case it is.
if it keeps going up even with the filling loop disconnected then you need a new plate heat exchanger.

Ian, April 2010