Worcester Bosch 28CDI pressure drop. Repair?

Hi! I have the above boiler and the pressure drops from 1.5 to 0.3 bar in a day. The " dump valve" is leaking and creates a puddle outside. Prior to this I had a couple of drops a week appearing from underneath the boiler somewhere.
Is this something easily fixed, How do I do it and is there something else I need to be concerned about?
David Clark, May 2006


done
either the pressure relief valve or "dump valve" as you called it is passing or the expansion vessel on the back of the boiler is flat and needs pumping up./ open the pressure relief valve, and use a foot pump the pump up the expansion vessel on the back of the boiler. its the big red disc on the backl opf the boiler.

craig plymouth, May 2006
link Click here to see other fixes for Worcester.