Dave asked ... Toilet Push Button not flushing properly?    |    Dave asked ... Repair kettle lid?    |    Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    Click here to ask your question

Ariston keeps losing pressure E02 error code comes up!?

My Ariston condenser boiler loses pressure when its not fired up.... looking at other posts I have checked for leaks and which there arent any but I put a bucket by the blow off pipe outside and that has filled up.... It works ok once I refill from the 2 taps on the boiler but when its off overnight its empty again in the morning.... any ideas??
Jason, April 2010
I have had a look at the pressure value which seems ok... it only lets the water out as it cools and the pressure doesnt seem to rise ?????HELP!!!!

Jason, April 2010
Either your expansion vessel has lost its charge or your pressure relief valve is faulty.

David, April 2010
link Click here to see other fixes for Ariston.