andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

sabre 24?

hi our boilers pressure keeps rising when switched off to over 2 when its set at one the day before we check it next morning and its at 2 we have to take some water from a radiator to bring it back down to 1 then it creeps up again to over 2 can some one help us solve this thanks
marjarie, June 2010
check filling loop letting by, disconnect flexy pipe and see water drips from shut of valve even if closed.

Or if there is plate DHW plate heatexchanger is in the boiler than is leaking to secondory circuit