Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

Carefeee !?

Hi ~ u kindly replied to a question a posted a day or so ago re danfoss 103 Timer and a Danfoss Thermostat ~ I've added some details you asked after your answer ~ could u take a look and see if that helps out? Thanks
Martin, July 2010
ok well thanks for trying anyhow. I may end up calling Danfoss and seeing what they say

Martin, July 2010
It won't allow me to put an e-mail address in (probably for the best I suppose), says invalid answer

Carefree, July 2010
Have u an email address? I could take a pic of the three wiring diagrams and forward them ... so happens Ive unearthed the wiring manual for the boiler : ))

Martin, July 2010
Ok, I'll give that a crack and let you know ~ really appreciate your help and patience.

Martin, July 2010
Right, I'll make an assumption, you currently use no.1 on the 103 for your switched live to the boiler and currently have a link between Terminal 6 (L) & terminal 3 in your timeswitch?

To wire the timeswitch and roomstat in series, you will need 4 core cable (3 sheathed and an earth).

Remove the current wire from term 1 on the timeswitch (label it as you will be using it later). the 3 wires on the new cable to the stat connect FROM the timeswitch as follows:

t/s=timeswitch
r/s= roomstat

#.1 on t/s to L on r/s.

#.5 (N) on t/s to N on r/s (N to N).

Link r/s L to #3 (as stated on r/s) on r/s instruction.

#.1 on r/s goes back to t/s and links with the

previous removed switchlive (from term 1 t/s)
These two wires can link in terminal 2 on the t/s wiring (as it's a spare)

Good luck

Carefree, July 2010