katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Kathy asked ... Samsung ER-4915?    |    Mark asked ... Oven door removal?    |    Click here to ask your question

No Hot water or heating?

Hi

I have an options volkera boiler the 2 lights at the front of the boiler are on all the time 1 yellow and 1 red, i have no hot water and also no heating can someone please give me some advise on this.

Thankyou
Craig, July 2010
This would indicate the system water pressure is low. It needs topping up to 1-1.5bar when the sytem is cold.
Unfortunately for you, the silly buggers at Volkera uniquely decided to hide the pressure guage inside the boiler. So removal of the front case is necessary to set correctly.
There are two screws hidden underneath the front cover, you need to undo these to get the cover off, then open the filling loop until the guage reads as above and reset the boiler.

Carefree, July 2010