Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

DRAINING A RADIATOR?

If I turn a Danfoss thermostatic radiator valve to zero, will it turn off the water so I can drain and remove the radiator ?

Thanks in antisipation. Keith.
Keith Howard, July 2006
Tip: Use a 5p piece, unscrew the head of the valve, insert a 5p piece into the bottom of the head, re-attach it to the valve body and then turn it to zero (Only good for very short term disconnects)

Don't forget to turn the other end of the rad off as well ;)

ccMods, July 2006
no you need to unscrew the thermo valve so you are just left with the brass pin sticking up in the middle and you should have a plastic cap usally blue and screw that on to where the thermo screwed on .if u dont have the cap u can get them from places like plumbcentre. just by shutting valve to zero does not shut the valve completly.

HI-SPEC PLUMBING, July 2006