Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    Click here to ask your question

no hot water?

hi again sorry about that i got a heatline combi 24 get heating but when open a hot tap water is cold
cheers matt
matt, September 2010
hetline is a derivative of the baxi potterton 80/105 performa boilers same problem with the hot water the diaphragm is probably at fault possibly split the baxi repair kit 511137 is what you may well need open a hot tap water will flow out look at the demand light on the front of the boiler if no demand light for hot water has ignited then its probably the rubber diaphragm split if you get the demand light lit and still no hot water then look at the 3 way valve assembly

byron, October 2010