Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

worcester bosch heatslave 20/25 pressure high and overflow active?

when hw and or ch is selected pressure rises past 3 bar and the overflow is active.
when turned off pressure reduces slightly but overflow still active.
all rads fully functional and hot.
smudge 5815, October 2010
Possibly overfilled, make sure the filling loop is turned off.
If the pressure rises significantlyon using HW/CH, it could be the expansion vessel needs re-charging/replacing.
If the 'overflow' continues to leak the prv has failed and will need replacing.

Carefree, October 2010