Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

How can I fix the problem of boiler pressure?

Re: Ferroli Optima 701

As soon as I top-up water level to Bar 2, the pressure keeps dropping and then the boiler stop function. I have to keep on topping up the water level in order to have it working.
Edwin Siau, October 2010
You have got a leak in the system, check the blow off pipe that runs to the outside of the building, if it is dripping water your pressure relief valve needs replacing, you will probably have some dirt under the seat.
Pressure valve may have lifted due to loss of air charge in pressure vessel.

Steve House, October 2010