Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

is this a common fault, ariston microgenus 2, pcb flame rectification probl?

flame rectification fault on ariston microgenus 2 combi gas boilers, approx 2 yrs old, requiring new p.c.b. ie, presence of flame not recognised, continues to spark, and locks out, requiring replacing of circuit board. ariston technical say its not a known fault, but this is my fourth such instance and i have two further boilers doing the same thing. tried drying out the pcb, checked earthing ok, electrodes clean / ok.
installer, southern ireland, October 2010
Yes this is a common fault with pcb, i am constantly repairing these pcb for engineers.

Dave, October 2010
link Click here to see other fixes for Ariston.